The CYCLE TIMER controls any 120V equipment such as irrigation pumps, fogger, fans or CO2 generators on periodic cycles. The output is repeatedly turned ON and OFF for periods corresponding to the ON and OFF times.

ON TIME from 1 to 60 minutes.OFF TIME from 5 minutes to 12 hours.3-Position SLIDE SWITCH to select the operating mode:

  • Day: Day cycle only.
  • 24-hour: Day & Night cycles.
  • Night: Night cycle only.

LIGHT SENSOR: Day/night detectorOUTPUT ON: Light indicator is lit when power is applied to the power/output cord (piggy back cord).

 

The COOLING THERMOSTAT controls cooling fans to maintain the room temperature at a value corresponding to the day or night set points.

Day & Night TEMPERATURE SET POINTS: 50°F to 100°F (10°C to 38°C)3-position Slide Switch to select differential:

  • +/- 2°F: Fan will start 2°F above set point and will stop 2°F below set point.
  • +/- 4°F: Fan will start 4°F above set point and will stop 4°F below set point.
  • +/- 6°F: Fan will start 6°F above set point and will stop 6°F below set point.

LIGHT SENSOR: Day/night detector.OUTPUT ON: Light indicator is lit when power is applied to the power/output cord (piggy back cord).External TEMPERATURE PROBE for accurate reading.

 

The FAN CONTROLLER automatically slows down or speeds up centrifugal fans to maintain the room temperature at a value corresponding to the day or night set points.

Day & Night TEMPERATURE SET POINTS: 50°F to 100°F (10°C to 38°C)3-position SLIDE SWITCH to select Idle options:

  • Idle Off: Fan will stop when set point is reached.
  • Idle On: Fan maintains minimum speed (idle) when room temperature is equal or cooler than set point.
  • Idle On with Low Temperature: Fan maintains minimum speed (idle) when room temperature is equal or cooler than set point BUT fan will stop if room temperature gets cooler than 10F below set point.

LIGHT SENSOR: Day/night detectorOUTPUT ON: Light indicator is lit when power is applied to the power/output cord (piggy back cord), regardless of the fan speed. Indicator is OFF when fan is defeated. External TEMPERATURE PROBE for accurate reading.

 

The LIGHT TIMER controls either lighting systems with a trigger cord, or standard and electronic ballasts (two 600W or one 1000W at 120V). Day cycles (ON cycles) last 12 or 18 hours, as selected by the user. An internal rechargeable battery maintains the cycles in the event of a power outage.

Real Time Clock Accuracy: time will drift less than 15 minutes in a year3-position SLIDE SWITCH to select ON/OFF Cycles (corresponding to Day/Night cycles):

  • 18h/6h: ON Time: 18 hours, OFF Time: 6 hours.
  • Reset Cycle: Hold 30 seconds to start a new ON cycle (to start the beginning of a new day cycle).
  • 12h/12h: ON Time: 12 hours, OFF Time: 12 hours.

Status Indicator:

  • SLOW BLINKING: to indicate the Hot Start delay is counting down.
  • BLINKING: to indicate the remaining time (number of hours left in the current cycle).
  • FLASHING (1-sec rate): to indicate the time countdown before the RESET is completed (30 seconds).
  • STEADY: to indicate the RESET has been completed.
  • QUICK FLASH: Warning! ON/OFF cycle selection has not been performed. Slide Switch forgotten in RESET position.

 

The Garden Controls CO₂ Controller will control any CO₂ generator or regulator to maintain the grow room CO₂ level around set point value.

  • Set Point Ranging from 500 to 1500 ppm
  • Day Only Operation
  • Easy Outdoor Calibration

LIGHT SENSOR: Day/night detectorOUTPUT ON: Light indicator is lit when power is applied to the power/output cord (piggy back cord).